Protector U-Joint Cover to fit standard size (1610, 1710, SPL 250, SPL170, SPL350, RPL20) H-D Truck U-Joints. Kit includes fasteners and 7 sets of mounting pads for installation on driveshafts with outside diameters from 4.00" to 4.590" |
4" to 4.59" Dia. Drive Shaft Mounted Kit for Standard U-Joints
Components Included Component P/N Quantity 7.625 x 5.340 D/S Mount U-Joint Cover 7634DS 2 Elastomeric Mount Pad for 4.00" Dia D/S 4000PD 4 Elastomeric Mount Pad for 4.095" Dia D/S 4095PD 4 Elastomeric Mount Pad for 4.213" Dia D/S 4213PD 4 Elastomeric Mount Pad for 4.331" Dia D/S 4331PD 4 Elastomeric Mount Pad for 4.500" Dia D/S 4500PD 4 Elastomeric Mount Pad for 4.540" Dia D/S 4540PD 4 Elastomeric Mount Pad for 4.590" Dia D/S 4590PD 4 For all heavy truck part numbers:
Step 1. Measure mounting surface diameter using deep-jaw calipers, a diameter tape measure (Stanley p/n 33-115 works well) or measure the circumference and divide by Pi (3.1417).
Step 2. Select the corresponding packet of 4 mounting-pads, the interchangeable pads are numbered to match the driveline diameters covered in the kit. Example: 4590PD fits 4.590” diameter.
Step 3. Affix the 4 mounting pads over the 2 attachment bars in each of the cover halves.
Step 4. Place the cover halves over the drive line, rotate as needed to accommodate balancing weights. A zip-tie is included to hold the cover in place (cut it off & discard once screws are tightened).
Step 5. Using a 4mm hex (Allen) driver, tighten the 12ea. M5 x 0.8 captive socket head screws. There is no need to overtighten, snug the fasteners as you would on any other lightweight cover.
* When installed properly, the cover will not move on the mounting surface. Using reasonable force on the open bell, if movement is visible at the mount area, switch-out 2 opposing pads (for balance) to the next smaller diameter.
To access grease fittings facing driveshaft with cover in-place
Step 1. Looking into the open end of the cover, visually align and mark a spot above and in-line with the zerk, on the sloping section of the cover.
Step 2. Using a 15.75mm or 5/8” diameter drill bit on slow speed, drill an access hole on the marked spot.
Step 3. Place the provided 5/8” diameter plug(s) into the access hole(s) in the cover.